Asus DS300j G2 Series User Manual page 239

Disk array subsystems
Table of Contents

Advertisement

a
s
raId C
ddInG a
eCond
If your ASUS DS300f G2 subsystem shipped with one RAID controller, you can add a second RAID controller.
The second controller must have:
• The same firmware version as the currently installed controller
• The same amount of SDRAM as the currently installed controller
To obtain information for the currently installed RAID controller:
1. Click the Device tab.
2. Click the Component List icon.
3. Click the Controller and click the View button.
4. On the Information tab, note the Firmware Version.
5. Click the Advanced information tab.
6. Note the Slot 1 and Slot 2 Memory Size.
7. Contact contact ASUS Storage Technical Support to order your second RAID controller.
ASUS Storage Technical Support prepares the new RAID controller with f'irmware and SDRAM to match the
existing RAID controller in your ASUS DS300f G2 subsystem.
233
ontroller
I
s
raId C
nstallInG a
eCond
To install a second RAID controller in your ASUS DS300f G2 subsystem:
1. Shut down the subsystem.
2. Remove the blank cover from the right RAID controller slot.
3. Carefully slide the new RAID controller into the slot until the handle locks in place.
4. Attach your data and management cables to the new controller, as needed.
See "Making Management and Data Connections" on page <?> for cable connection information.
5. Power up the subsystem and launch ASUS Storage Management.
6. In ASUS Storage Management, click the Dashboard tab and look under System Status.
• If the new controller has a green check
icon, the installation is completed. Go to "New Settings for Dual Controllers"
• If the new controller has a yellow !
icon, one of the RAID controllers went
into maintenance mode because its firmware or memory do not match the other
RAID controller. See "RAID Controller in Maintenance Mode," below.
raID c
m
m
ontroller In
aIntenance
To manage a RAID controller in maintenance mode:
1. Click the Administration tab.
2. Click the Firmware Update icon.
3. Click the Controller Firmware Update option.
4. Compare the Firmware version on Controller 1 and Controller 2.
• If the firmware versions are different, go to "Updating the Subsystem Firmware"
• If the firmware versions match, contact ASUS Storage Technical Support
for help installing the correct memory into the RAID controller.
n
S
D
c
ew
ettInGS for
ual
ontrollerS
With the second controller successfully installed, make the following settings:
• Redundancy Type – Set to Active-Active or Active-Standby.
See "Making Subsystem Settings (CLU)" on page <?>.
DS300f G2 Series User Manual
ontroller
oDe

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds300f g2 seriesDs300 g2 series

Table of Contents