Philips SOPHO 2000 IPS User Manual page 111

Hide thumbs Also See for SOPHO 2000 IPS:
Table of Contents

Advertisement

• For originating calls to the ISDN, do the following programming.
H
CM20
Assign ISDN access code to each trunk route
assigned by CM30 Y=00.
NOTE:
LCR can be used with ISDN-PRI.
Refer to Feature Programming
Manual.
CM08
Specify the timing start when making an ISDN
call from an attendant.
CM41
Specify the timing start when making an ISDN
call from a Single Line Telephone (PB/DP),
term
D
or Attendant Console, if required.
NOTE:
A # or timing start is used for outgoing ISDN calls when LCR is not invoked.
Example: 1-214-555-1212 is dialed from a D
and ship the digits only after the timing start timer has expired or # is dialed by the caller.
The # sign tells the PBX that dialing is completed.
I
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access code
(2)
100-163: Trunk Route 00-63
(1)
403
(2)
0 : Not available
1 : Available
Y=0
(1)
50
(2)
03-14: 3-14 seconds
If no data is set, the default setting is 10 seconds.
Recommended setting is 05 (5 seconds).
term
. The PBX will access a bearer channel
– 97 –
ISDN-PRI PROGRAMMING
DATA
NWA-008852-001 Rev.5.0
98ch3001.fm
NOVEMBER/15/2006

Advertisement

Table of Contents
loading

Table of Contents