System Outline of ISDN-BRI

The system is configured with a Basic Rate Interface Trunk (BRT) for the digital network interface. Since
the MP contains PLO, the system can be synchronized to the ISDN as a clock receiver office.
The figure below shows the system outline of ISDN-BRI.
SLT
LC
term
D
DLC
NOTE 1:
NT1 equipment must be installed in the premise.
NOTE 2:
We recommend the point-to-point connection when connecting the system to the public network
using the BRT card (Set the second data of CM35 Y=79 to 0).
For the point-to-multipoint connection using the BRT card, when the system is established far
from the public network, the communication error occurs easily because the ISDN signal fades
away.
System Outline of ISDN-BRI
PBX
2B
BRT
CLOCK
SIGNAL
TDSW
MP
(PLO)
– 7 –
CHAPTER 1 GENERAL INFORMATION
2-CHANNEL PCM
DIGITAL LINE (2B + D)
D
BRT : Basic Rate Interface Trunk
NT1 : Network Termination One
PLO : Phase Locked Oscillator
SYSTEM OUTLINE
NT1
ISDN