• For 4BRT (AP08-AP11 slot)
AP08
CN2
NOTE
08
07
06
05
04
03
02
01
NOTE:
Make the installation cable by using the connector attached with the PN-4BRTA-A card.
Example of MDF Cross Connection for BRT
PIM0
4BRT
RA
RB
No. 0
CIRCUIT
TA
TB
RA
RB
No. 1
CIRCUIT
TA
TB
2
TB
TA
No. 3
CIRCUIT
RB
RA
TB
TA
No. 2
CIRCUIT
RB
RA
INSTALLATION PROCEDURE FOR ISDN-BRI
LTC1
J
P
17
17
42
42
18
18
43
43
19
19
44
44
20
20
45
45
1
– 70 –
CHAPTER 2 INSTALLATION
MDF
RA
RB
TA
TB
RA
RB
TA
TB
RA
RB
TA
TB
RECEIVE
RA
RB
TA
TB
TRANSFER
Continued on next page
NWA-008852-001 Rev.5.0
TO NT1
TO NT1
TO NT1
TO NT1