LED INDICATION
LED
NORMAL
• 4BRT
RUN
Flash
(120 IPM)
ALM0
Off
ALM1
Off
ALM2
Off
ALM3
Off
Alarm Indications on BRT
FAULT
CAUSE
On or Off
Abnormal opera-
tion of BRT card
On
No. 0 circuit trans-
mission line fault
On
No. 1 circuit trans-
mission line fault
On
No. 2 circuit trans-
mission line fault
On
No. 3 circuit trans-
mission line fault
– 323 –
CHAPTER 5 OPERATION TEST
INTEROFFICE TRANSMISSION LINE TEST
FAULT
ACTION
Confirm the programming data:
1
CM05 Y=0/Y=1, CM07 Y=02.
Check to see if the SENSE switch
2
is set as per the AP number (04-
15, 20-31) assigned by CM05
Y=0.
3
Reset the MB switch
(Down→Up→Down)
4
If the fault cannot be cleared,
replace the card.
1
Confirm No. 0 circuit line status.
2
Confirm PSTN line status.
1
Confirm No. 1 circuit line status.
2
Confirm PSTN line status.
1
Confirm No. 2 circuit line status.
2
Confirm PSTN line status.
1
Confirm No. 3 circuit line status.
2
Confirm PSTN line status.