Interoffice Synchronization Test - Philips SOPHO 2000 IPS User Manual

Hide thumbs Also See for SOPHO 2000 IPS:
Table of Contents

Advertisement

Interoffice Synchronization Test

This test checks to see if noise occurs while calling with the opposite office, by difference of the clock
signal frequency between the offices. Do the following steps using "In Service" transmission lines.
STEP1: Originate an outgoing call via trunks.
STEP2: Check the speech quality (if noise, distortion or click occurs during a few minutes) with the op-
posite office mutually.
STEP3: On the DTMF telephone set, keep pressing any dial button, and check to see if noise periodical-
ly occurs on the DTMF signals coming from the calling station in the opposite office.
STEP4: Do the above test again in the opposite direction.
NOTE:
If noise periodically occurs, replace the MP card after checking the switch settings on the MP
card, and do the above test again.
CHAPTER 5 OPERATION TEST
– 328 –
PLO OPERATION TEST
NWA-008852-001 Rev.5.0
98ch5001.fm