System Conditions; Time Slot Assignment Condition - Philips SOPHO 2000 IPS User Manual

Hide thumbs Also See for SOPHO 2000 IPS:
Table of Contents

Advertisement

SYSTEM CONDITIONS

Time Slot Assignment Condition

As shown below, the DCH/ICH/BRT/2BRT card uses the time slot on the basic highway 4. Therefore, the
total number of time slots for all DCH/ICH/BRT/2BRT cards must be 128 time slots or less including all
other application processor cards, which use the highway 4.
The 24DTI/30DTI/24PRT/30PRT/4BRT/2ILCC card can use the time slot on both the basic and expanded
highway 4 and 6. Therefore, the total number of time slots for all 24DTI/30DTI/24PRT/30PRT/4BRT/
2ILCC cards must be 256 time slots or less including all other application processor cards, which use the
highway 4 and 6.
Accommodation of DTI/DCH/ICH/BRT/PRT into TDSW
FOR L/T CARDS: MAXIMUM 512 TIME SLOTS PER SYSTEM
FP0
FP1
FP2
FP3
BRT
DCH
ICH
PRT
HW4
DTI
BRT
HW6
ILC
(2ILCC)
FOR BASIC HIGHWAY4: MAXIMUM 128 TIME SLOTS PER SYSTEM
FOR EXPANDED HIGHWAY6: MAXIMUM 128 TIME SLOTS PER SYSTEM
FOR AP CARDS: MAXIMUM 256 TIME SLOTS PER SYSTEM
– 33 –
CHAPTER 1 GENERAL INFORMATION
MAXIMUM 128 TIME SLOTS
MAXIMUM 128 TIME SLOTS
MAXIMUM 128 TIME SLOTS
MAXIMUM 128 TIME SLOTS
2 TIME SLOTS/CARD (BRT)
4 TIME SLOTS/CARD (2BRT)
1 TIME SLOT/CARD
4 TIME SLOTS/CARD
24PRT: 25 TIME SLOTS/CARD
30PRT: 32 TIME SLOTS/CARD
24DTI: 24 TIME SLOTS/CARD
30DTI: 31 TIME SLOTS/CARD
8 TIME SLOTS/CARD (4BRT)
8 TIME SLOTS/CARD

SYSTEM CONDITIONS