Switch Settings
SWITCH NAME
SENSE
(Rotary SW)
F
4
NOTE 1
MB (Toggle SW)
ON
NOTE 2
SW2 (Piano SW)
OFF
8
7
6
5
4
3
2
1
ON
SWITCH
SETTING
NUMBER
POSITION
4-F
Set the switch to match the AP Number (04-31) to be
set by CM05.
SW4-8: ON
AP No.
SW4-8: OFF
SW No.
0-3
Not used
UP
DOWN
ON
1
OFF
ON
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
ON
8
OFF
FUNCTION
04 05 06 07 08 09 10 11 12 13 14 15
20 21 22 23 24 25 26 27 28 29 30 31
4
5
6
7
8
9
For make-busy
For normal operation
Remote loopback (No. 0 Circuit)
Normal operation
Remote loopback (No. 1 Circuit)
Normal operation
Not used
Not used
Not used
Not used (Always set to OFF)
Not used
AP No. 04-15
AP No. 20-31
– 313 –
PN-2ILCC (ILC)
A
B
C
D
E
F
Continued on next page