LED INDICATION
LED
NORMAL
RUN
Flash
(120 IPM)
PCM
Off
FRM
Off
MFRM
Off
RMT
Off
MRMT
Off
AIS
Off
Alarm Indications on 30DTI
FAULT
CAUSE
On or Off
Abnormal opera-
tion of DTI card
On
No PCM signals
arrive from the dis-
tant office
On
Frame Alignment
signals from the
distant office can-
not be received
On
Multi Frame Align-
ment signals from
the distant office
cannot be received
On
Frame Alignment
signals cannot be
sent to the remote
PBX
On
Multi Frame Align-
ment signals cannot
be sent to the
remote PBX
On
Remote PBX is in
the local loopback
state
– 318 –
CHAPTER 5 OPERATION TEST
INTEROFFICE TRANSMISSION LINE TEST
FAULT
ACTION
1
Confirm the programming data:
CM05 Y=0/Y=1, CM07 Y=01.
2
Check to see if the SENSE switch
is set as per the AP number (04-
15, 20-31) assigned by CM05
Y=0.
3
Reset the MB switch
(Down→Up→Down)
If the fault cannot be cleared,
4
replace the card.
1
Check to see if the line is correctly
connected to the DTI card.
2
Plug and unplug the DTI card.
Repeat this two or three times.
1
Check the receive line and exter-
nal equipment.
2
Replace the remote DTI card.
1
Check the receive line and exter-
nal equipment.
2
Replace the remote DTI card.
1
Check the transmission line and
external equipment.
2
Replace the DTI card.
1
Confirm the switch setting on the
DTI card indicating an alarm.
Replace the DTI card not indicat-
2
ing an alarm, with a spare.
Check the switch settings of the remote
DTI card.
NWA-008852-001 Rev.5.0