Mitsubishi Electric GOT2000 Series Connection Manual page 907

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Device name
PD23, PD1023
PD24, PD1024
PD25, PD1025
PD26, PD1026
PD27, PD1027
PD28, PD1028
PD29, PD1029
PD30, PD1030
PD31, PD1031
PD32, PD1032
PD33, PD1033
PD34, PD1034
PD35 to PD40, PD1035 to PD1040
PD41, PD1041
PD42, PD1042
PD43, PD1043
PD44, PD1044
PD45, PD1045
PD46, PD1046
PD47, PD1047
PD48, PD1048
*1
For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after
setting the parameter data.
(9) Extension setting No.2 parameter
Device name
PE1, PE1001
PE2, PE1002
PE3, PE1003
PE4, PE1004
PE5, PE1005
PE6, PE1006
PE7, PE1007
PE8, PE1008
PE9, PE1009
PE10, PE1010
PE11 to PE33, PE1011 to PE1033
PE34, PE1034
PE35, PE1035
PE36 to PE40, PE1036 to PE1040
PE41, PE1041
PE42 to PE43, PE1042 to PE1043
PE44, PE1044
PE45, PE1045
PE46, PE1046
PE47, PE1047
PE48, PE1048
PE49, PE1049
Item
Output device selection 1
Output device selection 2
Output device selection 3
Output device selection 4
For manufacturer setting
Output device selection 6
Response level setting
Function selection D-1
Function selection D-2
Function selection D-3
Function selection D-4
Function selection D-5
For manufacturer setting
Input signal automatic on selection 3
Input signal automatic on selection 4
Input device selection 11L
Input device selection 11H
Input device selection 12L
Input device selection 12H
Output device selection 7
For manufacturer setting
Item
Fully closed loop function selection 1
For manufacturer setting
Fully closed loop function selection 2
Fully closed loop control - Feedback pulse electronic gear 1 - Numerator
Fully closed loop control - Feedback pulse electronic gear 1 -
Denominator
Fully closed loop control - Speed deviation error detection level
Fully closed loop control - Position deviation error detection level
Fully closed loop dual feedback filter
For manufacturer setting
Fully closed loop function selection 3
For manufacturer setting
Fully closed loop control - Feedback pulse electronic gear 2 - Numerator
Fully closed loop control - Feedback pulse electronic gear 2 -
Denominator
For manufacturer setting
Function selection E-3
For manufacturer setting
Lost motion compensation positive-side compensation value selection
Lost motion compensation negative-side compensation value selection
Lost motion filter setting
Torque offset
Lost motion compensation function selection
Lost motion compensation timing
15.6 Device Range that Can Be Set
*1
Symbol
*DO1
*DO2
*DO3
*DO4
*DO6
*DIF
*DOP1
*DOP2
*DOP3
*DOP4
*DOP5
*DIA3
*DIA4
*DI11L
*DI11H
*DI12L
*DI12H
*DO7
*1
Symbol
*FCT1
*FCT2
*FBN
*FBD
BC1
BC2
DUF
FCT3
*FBN2
*FBD2
EOP3
15
LMCP
LMCN
LMFLT
TOF
*LMOP
LMCD
15 - 85