When using a PLC CPU in the direct mode

Note that when the I/O control mode of the PLC CPU is the direct mode, and if the 1st GOT is connected to the main or
extension base unit with a 5m extension cable (GT15-AC50B, GT15-A1SC50NB), the input X of the empty I/O slot cannot
be used.
No restrictions apply when the I/O control mode is the refresh mode.
On PLC CPUs whose I/O control mode can be selected by a switch, set the I/O control mode to the refresh mode before
use.
8.4.14
When connecting to a Q4ARCPU redundant system
■1. When the GOT is bus-connected to a Q4ARCPU redundant system
Connect the GOT to the last redundant extension base unit (A68RB) of the Q4ARCPU redundant system.
For the redundant extension base units, use version B or later.
The version can be confirmed in the DATE field of the rating plate.
POINT
POINT
POINT
In the cases where input X of an empty I/O slot is used
(1) When input X is assigned on the MELSECNET/10 network
(2) When input X of an empty I/O slot is turned ON/OFF by the computer link module
(3) When input X of the I/O slot is turned ON/OFF by the touch switch function (Bit SET/RST/
Alternate/Momentary) of GOT
Version of redundant extension base unit
Enlarged view of rating plate
POINT
POINT
POINT
Precautions for Q4ARCPU redundant system configurations
The GOT does not operate normally in the following system configurations.
(1) When the GOT is bus connected to the bus switching module (A6RAF) on a redundant main
base unit (A32RB/A33RB)
(2) When the GOT is bus connected to a version-A redundant main base unit (A68RB)
Caution
8 - 45
8.4 Precautions