Step 2.
Set the trigger action.
Set the trigger action so that the station number is switched when the faulty station information (SW70) of
MELSECNET/H turns ON in the project specified by choosing [Common]
Condition 1 : SW70.b0 (while ON)
Operation
: GD100=2
Condition 1 : SW70.b1 (while ON)
Operation
: GD100=1
Make the setting so that the station number is switched when the faulty station information (GS231) from
the station monitoring specified by selecting [Common]
Condition 1 : GS231.b0 (while ON)
Operation
: GD100=2
Condition 1 : GS231.b1 (while ON)
Operation
: GD100=1
When b0 is ON, Station No. 1 is abnormal.
Screen No. is changed to 2.
When b1 is ON, Station No. 2 is abnormal.
Screen No. is changed to 1.
[trigger action] turns ON.
When b0 is ON, Station No. 1 is abnormal.
Screen No. is changed to 2.
When b1 is ON, Station No. 2 is abnormal.
Screen No. is changed to 1.
4.2 MELSEC Q Series
[trigger action].
4 - 83