Plc Side Setting - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

6.5

PLC Side Setting

When a GOT and an LCPU are connected via an L6ADP-R4 adapter, set the following communication setting.
6.5.1
L6ADP-R4 adapter settings
Set the communication settings by the DIP switches of the L6ADP-R4 adapter.
*1
■1. DIP switches (SW1 to SW3)
Set the data length, parity bit, and stop bit.
Setting switch
SW1
SW2
SW3
*1
■2. DIP switches (SW4 to SW6)
Set the transmission speed.
Setting switch
SW4
SW5
SW6
*1
6 - 54
6.5 PLC Side Setting
L6ADP-R4
SD
RD
SW
DATA 1
PARITY
STOP
BAUD0
BAUD1
BAUD2
RS-422/485
SDA
SDB
RDA
RDB
SG
(FG)
SW7 and SW8 are not used.
Description
*1
Data length
*1
Parity
*1
Stop bit
Adjust the settings with GOT settings.
6.4.2 Communication detail settings
9600
bps
ON
ON
OFF
Adjust the settings with GOT settings.
6.4.2 Communication detail settings
ON
2
3
4
DIP SWITCH
5
SW1 to 8
6
7
8
Transmission speed
19200
38400
bps
bps
OFF
ON
OFF
OFF
ON
ON
*1
Setting range
OFF
ON
OFF
ON
OFF
ON
*1
57600
bps
OFF
ON
ON
7bit
8bit
Disable
Enable
1bit
2bit
115200
bps
ON
ON
ON