Mitsubishi Electric GOT2000 Series Connection Manual page 626

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

11.3.2
Communication detail settings
Make the settings according to the usage environment.
Item
*4
Network Type
Network No.
Station No.
Group No.
Mode Setting
Tramsmission Speed
Reflesh Interval
Input for Error Station
Retry
Timeout
Time
Delay Time
*4
Monitor Speed
Servo axis switching GD
device head No.
*1
*2
*3
*4
11 - 10
11.3 GOT side settings
Set the network Type
Set the network No. of the GOT.
(Default: 1)
Set the station No. of the GOT.
(Default: 1)
-
Set the operation mode of the GOT.
(Default:
Online (auto. reconnection))
-
Set the number of refreshes to secure the send/receive data in station units during communication.
(Default: 25ms)
Set the hold/clear of input from the station where the data link is faulty due to some reason such as
turning the power OFF.
(Default: Clear)
Set the number of retries to be performed when a communication timeout occurs.
When receiving no response after retries, the communication times out.
(Default: 3times)
Set the time period for a communication to time out.
(Default: 3sec)
Set the delay time for reducing the load of the network/destination PLC.
(Default: 0ms)
Set the monitor speed for the CC-Link IE field network.
This setting is not valid in all systems.
(Default: High(Normal))
Set the servo axis switching GD device head No.
(Default: 10)
For details, refer to the following POINT.
(5) Indirect specification of the servo axis No.
For details, refer to the following manual.
CC-Link IE Field Network Master/Local Module User's Manual
This range is effective when collecting a large amount of data (such as logging and recipe function) on other than the monitor
screen.
However, the range may affect the sequence scan time when connecting to Q00UJ/Q00U/Q01U/Q02UCPU.
If you want to avoid the influence on the sequence scan time, do not set [High(Normal)].
(This setting hardly affects QCPUs other than the above.)
Set this range if you want to avoid the influence on the sequence scan time further than the [Middle] setting when connecting to
Q00UJ/Q00U/Q01U/Q02UCPU.
However, the monitor speed may be reduced.
When using a global label, to read or write more than 235 two-byte characters, set the [Monitor speed] to [High (Standard)] or
[Middle].
If [Monitor speed] is set to [Low], a system error occurs when reading or writing.
For details, refer to the following manual.
GT Designer3 (GOT2000) Screen Design Manual
Description
Range
• CC IE Field
1 to 239
1 to 120
0 (fixed)
• Online
• Offline
*1
• H/W test
*1
• Self-loopback test
1 Gbps (fixed)
1 to 1000ms
Clear/Hold
0 to 5times
3 to 90sec
0 to 300ms
*2
High(Normal)
/
*3
Middle/Low
0 to 65520

Hide quick links: