■2. GX Works2 network parameter Ethernet/CC IE/MELSECNET
For details of the setting contents of PLC side, refer to the following manual.
(1) Network Type, Network No., Total Stations setting
Example: Master station setting
Network type
Network No.
Total Stations
Station No.
(2) Routing parameter setting
Set the followings as necessary.
Up to 64 [Transfer Network No.]s can be set.
However, the same transfer network number cannot be set twice or more (multiple times).
Therefore, the one that can access to other station from the request source host GOT is 64 kinds of [Transfer
Network No.]s.
Transfer Network No.
Relay Network No.
Relay Station No.
5 - 96
5.4 PLC Side Setting
MELSEC-Q CC-Link IE Field Network Master/Local Module User's Manual
Item
Item
Set value
Master station
CC IE Field
(Master station)
1
2
0 (fixed)
1 to 239
1 to 239
0 to 64
Local station
CC IE Field
(Local station)
1
-
2
Range