5. Connect the harnesses (DR1-RP, DR2-RP6 and DR66-RP6) to the connectors (CN1 to CN4, CN6
and CN7) on the RP-107 board.
n
Connect the harnesses referring to the figure below. (Make the white and red harnesses upright and
the blue and yellow harnesses lay)
If not, it is impossible to make full use of this unit's properties.
6. Securely connect the RP-107 board to the connectors on the mother board.
7. Connect the harnesses to CN5 and CN102 on the RP-107 board.
8. Fix the acoustic isolation plate to the chassis with two screws (BPWH2.6 x 5).
9. Tighten the screwsc and securely attach the RP-107 board to the acoustic isolation plate.
10. Attach the RP shield plate as to putting the convex portion of the RP shield plate into the clearance
between screws and acoustic isolation plate, then fix with screws (APWH2.6 x 5).
11. Attach the upper frame. (For the installation, refer to "1-6. Removal/Installation of Cabinet" of the
maintenance manual Part 1.)
RP shield plate
Convex portions
BVW-55 P2
Red
CN7
Yellow
CN3
CN4
CN6
CN102
CN2
Blue
Acoustic isolation plate
B
PWH2.6 x 5
A
PWH2.6 x 5
RP-107 board
White
CN5
Orange
CN1
C
1-1. Board Extension
A
PWH2.6 x 5