Interconnecting An Additional Drive Object - Siemens SINAMICS S120 Commissioning Manual

Canopen interface
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
3.6 Interconnecting process data in the receive and transmit buffers
1. In the project navigator, search for the p parameter p8851 [3] by choosing Drive_1 > right-
2. Interconnect parameter p8851 [3] = PZD 4 with the associated r parameters (r0080).
Actual position value (PZD 5+6 32 bit)
The following table shows the p parameter for the actual position value, which has to be
interconnected with the corresponding source.
Table 3- 22
Target (sink)
PZD 5+6
p8861 [4]
Interconnect p parameter p8851 [3] with r parameter r0482 for the actual position value by
carrying out the following:
1. In the project navigator, search for the p parameter p8861 [4] by choosing Drive_1 > right-
2. Interconnect parameter p8861 [4] = PZD 5 + 6 with the associated r parameters (r0482
3.6.2.3

Interconnecting an additional drive object

Steps
To interconnect the next drive object (Single Motor Module 2), repeat the steps described in
"Interconnecting transmission message frames in the receive buffer" and "Interconnecting
transmission message frames in the transmit buffer".
When carrying out the steps, choose Drive_2 in the project navigator.
118
click > Expert > Expert list.
Interconnect the actual position value
click > Expert > Expert list.
[0...2]) for the appropriate encoder.
Source
Meaning
r0482
Actual position value
Commissioning Manual, (IH2), V2.6, 10/2008 Edition, 6SL3097-2AA00-0BP3
CANopen interface

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents