Lighting control console
Table of Contents

Advertisement

EFFECT Screen
6)
Resetting the specification of CHs or CUEs for a STEP as a batch
> STEP number = RESET ↵
Example) Resetting the specification of CHs or CUEs for STEP5 as a batch.
> STEP5 = RESET ↵
7)
Specifying time control for a STEP
> STEP number = F6 (T.CNT) ↑ or ↓ ↵
Example) Specify time control CUT for STEP1 and STEP3.
> STEP1 + 3 = T.CNT ↵
In this case, the window below is displayed. Select an item with ↑ or ↓.
TIMECNT
CUT111
1
FADE
When time control is set for a STEP, the Batch-STEP mode is disabled.
8)
Specifying a time for a STEP
> STEP number = F7 (TIME) Time ↵
Example) Specify 2 seconds of TIME for STEP2 and STEP4 to STEP5.
> STEP2 + 4 ~ 5 = TIME2 ↵
When TIME is set for a STEP, the Batch-STEP mode is disabled.
9)
Specifying time control for all STEPs
> STEP number 0 = F6 (T.CNT) ↑ or ↓ ↵
Example) Specify FADE for time control for all STEPs.
> STEP0 = T.CNT ↵
In this case, the window below is displayed. Select an item with ↑ or ↓.
TIMECNT
CUT
FADE
11 1
NO SET
When time control over all STEPs is set, the time and time control for each STEP is disabled.
When NO SET is specified, the time and time control for each step is enabled.
17-6