WORKING LIGHT PANEL/GM PANEL

WORKING LIGHT PANEL

1.
Function
The WORKING LIGHT PANEL controls automatically the dimmer assigned to it within the upper and
lower limits of the range.
2.
Operation Description
1)
Setting the upper and lower limits
Set the upper and lower limits using the UPPER fader and the LOWER fader.
Upper limit value: the UPPER fader value is the upper limit of the WORKING LIGHT.
Lower limit value: the LOWER fader value is the lower limit of the WORKING LIGHT.
2)
Setting the dimming speed during automatic dimming
Set a speed value between 0 second to 59.9 seconds with the speed setting switches SLOW and
FAST.
The setting is displayed on the speed indicator.
For fast forwarding, hold the button down.
SLOW button: Increments the speed value in the SPEED indicator in units of 0.1 seconds. (Fading is
slowed.)
FAST button: Reduces the value in the SPEED indicator in units of 0.1 seconds. (Fading is sped up.))
3)
Automatic dimming to the upper limit value
* The upper limit value is controlled by the UPPER and LOWER faders of the WORKINGH LIGHT.
Press the
button.
The level value of the WORKING LIGHT fades toward the UPPER fader value in the period indicated on
the SPEED indicator, and the dimming level is output to the dimmer assigned.
The master value of the WORKING LIGHT is indicated on the LED bar graph beside the UPPER and
LOWER faders.
4)
Automatic dimming to the lower limit value
* The lower limit value is limited by the UPPER and LOWER faders of the WORKING LIGHT.
Press the
button.
The level value of the WORKING LIGHT fades toward the LOWER fader value in the period indicated on
the SPEED indicator, and the dimming level is output to the dimmer assigned.
The master value of the WORKING LIGHT is indicated on the LED bar graph beside the UPPER and
LOWER faders.