1. GETTING STARTED
(*1) For information about the naming of the user input module and how to operate and adjust the
device, refer to the user's manual that comes with the device.
(*2) For information about the length of each connection cable, see "5.5.3 External interface cable
length specifications". The mouse and keyboard connection cables must be directly connected
to this equipment. Do not use extension cables for them. If you use extension cables, the
mouse or keyboard may not work properly.
(*3) When you connect USB devices to the USB connectors, pay attention to the orientation of the
connector. In addition, in the USB port, a USB cable may fall out from the connector by the
unexpected contact because there is not the locking mechanism of the connector in a standard.
When you install this equipment, fix USB cables if it is necessary.
In order to conformity the EMC standards (VCCI, FCC,CE), use shielded cables for the
(Note)
interface cables (display interface cable, keyboard interface cable, and mouse interface cable)
connected to the equipment.
 Connecting to an outlet (
Plug the power cable that attached the optional AC adapter into a grounded outlet
completely. (*1)
(*1) If you have no other choice than to use an outlet without a grounding pole that is
properly grounded, use 3-pole to 2-pole conversion adapter and connect the green
ground line from the adapter to the ground of the outlet. A user must verify the proper
functionality of the 3-pole to 2-pole conversion adapter before using it.
< NOTE >
The power cable attached to AC adapter is rated at the input voltage of 125VAC.
When using this optional AC adapter at over 125 VAC, prepare the power cable
which fit input voltage and inspect the safeness of this equipment enough.
When using optional AC adapter
Make sure you use a power cable with
a 2-pole plug with a grounding pole.