2. OPERATION

2.4 Power Shutdown

1.
Confirm that the equipment is shut down. (See "2.3 Shutting Down the Equipment".)
2.
Unplug the optional AC adapter power cable plug from the outlet. Or unplug the
power cable directly from the DC power connector on the equipment.

2.5 Emergency Shutdown

In case of smoke, a burning smell, or the like, unplug the power cable from
the outlet, and contact your dealer or maintenance personnel. Using faulty
equipment without repair may result in a fire or an electric shock.
● Performing emergency shutdown (e.g. unplug the power cable from the DC
power connector without shutting down the OS, unplug the power cable of
optional AC adapter from the outlet, or turn off the circuit breaker.) may cause
the OS or applications not to work properly or may cause saved data to be
corrupted. Do not perform emergency shutdown unless you must stop the
system immediately due to some kind of error.
● If you turn off power at the source of power supply, the system may not be able
to recover automatically.
In the following cases, turn off the power at the source of the power.
・When the equipment shows an error condition and you have to shut down the power
immediately (for example, when a burning smell is detected).
・When you cannot shut down the equipment due to some error.
・When the power is turned off repeatedly or only the auxiliary power supply is on due to
excess current or overheating.
Also, in the following cases, either disconnect the power cable from the DC power
connector of the equipment or unplug the power cable of the optional AC adapter from the
outlet, or shut off the power at the power supply source.
・If the fan is stopped and the temperature gets too high or too low and consequently the
power is automatically turned off to protect the equipment and only the auxiliary power
supply is on, after the OS starts, when a stopped fan is detected, the OS is automatically
shut down and then the power is turned off (When already RAS was installed).
WARNING
NOTICE
2-4