Data Description
8.2 Parameters for SINAMICS S120
r9795
SI diagnostics STOP F (Control Unit)
Displays the number of the cross- -checked data which has caused STOP F on
the Control Unit.
See also: r9895 and F01611
The complete list of numbers for the crosswise compared data is listed in fault
F01611.
Unit:
Default value:
- -
- -
r9798
SI actual checksum SI parameters (Control Unit)
Displays the checksum over the checked Safety Integrated parameters on the
Control Unit (actual checksum).
See also: p9799, r9898
Unit:
Default value:
- -
- -
p9799
SI reference checksum SI parameters (Control Unit)
Sets the checksum for the checked Safety Integrated parameters on the
Control Unit (reference checksum).
The actual checksum (r9798) calculated by the CU must be entered into the
reference checksum p9799. This therefore acknowledges the safety com-
missioning on the Control Unit for the basis functions integrated in the drive.
See also: r9798, p9899
Unit:
Default value:
- -
0000 hex
8-478
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
0000 hex
FFFF FFFF hex
Checksum:
Protection level:
No
2
Data type:
Effective:
--
Unsigned32
Checksum:
Protection level:
No
3
Data type:
Effective:
--
Unsigned32
Checksum:
Protection level:
No
3
Data type:
Effective:
Unsigned32
When exiting SI- -