Siemens Sinumerik 840D sl Function Manual page 723

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
27240
Parameter
Explanation
Response
Remedy
Program
r
continuation
27241
Parameter
Explanation
Response
Remedy
Program
r
continuation
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
PROFIsafe: PLC not booted, information: %1
%1 = actual information from the PROFIsafe boot NCK--PLC
There is no PROFIsafe configuration available to the NCK after the
time specified using the MD10120 $MN_PLC_RUNNINGUP_TI-
MEOUT.
The current status of the PROFIsafe boot NCK--PLC is displayed in the
alarm text:
-- 0 = configuration not available, interface to the NCK is not
supported by FB15.
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Increase MD10120 $MN_PLC_RUNNINGUP_TIMEOUT
check the PLC operating state
check the PLC operating system software release
delete the F parameterization in the NCK--MD
Switch control system OFF and ON again.
PROFIsafe: Version different, NCK: %1, PLC: %2, (%3)
%1 = version of the interface on the NCK side
%2 = version of the interface on the PLC side
%3 = internal identifier of the interface
The interface required has been implemented differently for the NCK
and PLC components. The F communications cannot be initialized.
The alarm text contains the following information:
-- Version of the interface on the NCK side (%1)
-- Version of the interface on the PLC side (%2)
-- Internal identifier of the interface (%3)
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the PLC operating system and correct NCK software versions.
Upgrade the PLC operating system.
Delete NCK F parameterization.
Switch control system OFF and ON again.
10.2NCK safety alarms for Sinumerik 840D sl
Diagnostics
10-723

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents