Response
Program
r
continuation
27002
Parameter
Explanation
Response
Remedy
Program
r
continuation
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Remedy
Check the Sensor Module.
1024
Saved standstill positions of NCK and PLC different.
Remedy
Re--establish data consistency using power on.
1025
The drive or encoder signaled "parking active" -- however the control
had not requested "parking axis".
Remedy
Check the control signals to select the "parking" state.
1026
Plausibility error for cam synchronization between NCK and PLC.
Remedy
Check communication between the PLC and drive and between PLC
and NCK.
NC start disable in this channel
Alarm display
A STOP F was initiated. If a safety monitoring function was active
(SBH, SG, SE, SN), then a STOP B was also automatically initiated.
It is then necessary to power--down/power--up the control (power on).
Clear the alarm with the RESET key. Restart the part program.
If a STOP B was initiated, then the control must be power--down/
powered--up (power on).
Axis %1 Test stop in progress
%1 = axis name, spindle number
The proper and correct functioning of the shutdown path is presently
being tested by setting the SGE "test stop selection".
Alarm display
This message only provides information for the user.
The alarm is no longer displayed when the alarm cause has been
removed. No other operator actions are required.
The alarm automatically disappears after the delay time has expired
that is defined in MD36957 $MA_SAFE_PULSE_DIS_CHECK_TIME --
and the withdrawal of the SGE "test stop selection" if the control
detects that the drive pulses have been cancelled -- i.e. the test has
been successfully completed. An unsuccessful test can be recognized
as a result of Alarm 27001 with fault code 1005 or Alarm 27024.