Diagnostics
10.2 NCK safety alarms for Sinumerik 840D sl
r
Program
continuation
27224
Parameter
Explanation
Response
Remedy
Program
r
continuation
27225
Parameter
Explanation
Response
Remedy
Program
r
continuation
10-722
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Switch control system OFF and ON again.
PROFIsafe: F module MD %1[%2]
PROFIsafe- -Adresse
assignment
%1 = MD name 1
%2 = MD field index 1
%3 = MD name 2
%4 = MD field index 2
In the NCK MD or in the S7 F parameters, the same PROFIsafe
address has been parameterized for the F modules parameterized in
the specific machine data. This means that a clear communications
relationship between the F master and F slave is not possible.
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check and correct the S7 F parameterization and NCK--MD.
Switch control system OFF and ON again.
PROFIsafe: Slave %1, configuration error, %2
%1 = PROFIBUS slave address
%2 = configuration error
An error has occurred during the evaluation of the S7 PROFIBUS
configuration for the specific slave. This is further specified in alarm
parameter %2.
%2 = PRM header: The PRM telegram for this slave could not be
clearly interpreted (is currently not initiated).
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the S7 PROFIBUS configuration and correct.
Switch control system OFF and ON again.
MD %3[%4]: Double