There are three options available to evaluate the temperature:
Option
Temperature channel 1 via the SMC30
encoder interface X23.
Temperature channel 1 via terminal X120,
for example, if an encoder is being used.
Two temperature channels via X23 and
X120. Encoder interface X23 is assigned to
temperature channel 1 and terminal X120 is
assigned to temperature channel 2.
CUA31
The parameterization of the temperature evaluation via terminal X210 can be performed
using the STARTER screen (messages and monitoring > motor temperature). "Temperature
sensor via Motor Module (11)" should be selected in the "Temperature sensor selection"
field. The temperature of the sensor is displayed in r0035.
CUA32
The parameterization of the temperature evaluation via terminal X210 or sub D socket X220
is performed using two temperature channels.
p0600 = 11: Temperature sensor via Motor Module
For the SINAMICS S120 AC Drive (AC/AC) and if Control Unit Adapter CUA31/CUA32 is
used, the temperature sensor connection is on the adapter (X210).
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
2.16 Temperature sensors for SINAMICS components
The following parameter settings must be made:
p0600[0..n] = 1: Selects the encoder (1, 2 or 3), which is assigned to
encoder interface X23 and via which the temperature is evaluated (n =
motor data set).
p0601[0..n] = 1 or 2: Selection of the temperature sensor type, n = motor
data set
r0035: Display of the temperature value.
p0600[0..n] = 11: Activation from temperature channel 1 via terminal
X120
p0601[0..n] = 1 or 2: Selection of the temperature sensor type, n = motor
data set
r0035: Display of the temperature value.
p0600[0..n] = 1: Selects the encoder (1, 2 or 3), which is assigned to
encoder interface X23 and via which the temperature is evaluated (n =
motor data set).
p0601[0..n] = 10: Evaluation via several temperature channels
p4600[0..n]: Selection of the temperature sensor type from temperature
channel 1, n = encoder data set
p4601[0..n]: Selection of the temperature sensor type from temperature
channel 2, n = encoder data set
r4620[0...3]: Reading the temperature values.
Index n = 0 temperature channel 1
Index n = 1 temperature channel 2
r0035: Display of the higher temperature value of temperature channels
1 and 2.