Siemens SINAMICS S120 Commissioning Manual page 48

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Preparation for commissioning
1.5 Rules for wiring with DRIVE-CLiQ
Drive line-up comprising four Motor Modules in the chassis format with different pulse frequencies
It is advantageous to connect Motor Modules with different pulse frequencies to different
DRIVE-CLiQ sockets of the Control Unit. They may also be connected at the same DRIVE-
CLiQ line.
In the following diagram, two Motor Modules (400 V, output ≤ 250 kW, pulse frequency
2 kHz) are connected to interface X101 and two Motor Modules (400 V, output > 250 kW,
pulse frequency 1.25 kHz) are connected to interface X102.
Note
The offline topology automatically generated in the STARTER commissioning tool must be
manually modified, if this topology was wired.
Figure 1-7
Drive line-up in chassis format with different pulse frequencies
46
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Commissioning Manual

Advertisement

Table of Contents
loading

Table of Contents