Commissioning
2.2 STARTER commissioning tool
Create data records (offline) and copy
Drive and command data sets (DDS and CDS) can be added in the drive's configuration
screen. Click on the appropriate buttons to do this. Before data sets are copied, all the wiring
needed for both data sets should be completed.
For more information about data sets, refer to Chapter "Basics of the drive system" in the
SINAMICS S120 Function Manual Drive Functions.
Load project to target device.
You can use this function to load the actual project from the programming device into the
Control Unit. A consistency check is first made for the project. If inconsistencies are
detected, corresponding messages are output. You must resolve the inconsistencies before
loading. If the data are consistent, then they will be transferred into the work memory of the
Control Unit. In order to execute this function in the online mode, the following operator
actions are alternatively available:
1. Select the drive unit and call the menu "Project > Load to target system".
2. Select the drive unit and call the shortcut menu "Target device > Load to target device".
3. Select the drive unit and call the menu "Target system > Load > Load CPU/drive unit to