Siemens SINAMICS S120 Function Manual page 185

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Subject
Position interface via PROFIdrive
for higher-level motion control
Encoderless speed control
Motor data identification
Speed controller tuning
V/f control
Encoderless
closed-loop torque control
Field-weakening range for
induction motors
Maximum output frequency with
closed-loop control
Note:
The derating characteristics in the various manuals must be carefully observed!
Max. output frequency when using dv/dt and sine-wave filters: 150 Hz
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Servo control
Yes
Yes, as of 10% rated motor speed,
open-loop controlled operation below
this
Yes
Yes
Yes
No
≤ 16 x field-weakening threshold speed
(with encoder)
≤ 5 x field-weakening threshold speed
(without encoder)
2600 Hz with 31.25 μs / 16 kHz
1300 Hz with 62.5 μs / 8 kHz
650 Hz with 125 μs / 4 kHz
300 Hz with 250 μs / 2 kHz
Note:
SINAMICS S can achieve the specified
values without tuning.
Higher frequencies can be set under
the following secondary conditions and
additional tuning runs:
Up to 3000 Hz
Operation without an encoder
In conjunction with controlled
infeeds
Up to 3200 Hz
Operation with encoder
In conjunction with controlled
infeeds
Absolute upper limit 3200 Hz
Vector control
Yes
Yes (for ASM and PEM from standstill)
Yes
Yes
Yes (various characteristics)
Yes, as of 10% rated motor speed, open-
loop controlled operation below this
≤ 5 x rated motor speed
300 Hz with 250 μs / 4 kHz
or with 400 μs / 5 kHz
240 Hz with 500 μs / 4 kHz
Note:
If a higher output frequency is required,
consult the specialist support from
SIEMENS.
Vector control
185