Siemens SINAMICS S120 Function Manual page 412

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
7.28 Web server
5. Select the drive object in the "DO" drop-down list.
Figure 7-39
6. Enter the parameter of the drive object in the following input fields (e.g. 601:0).
– First field: Parameter number
– Second field: Index
– Third field: Bit number
The parameter name is now displayed on the right of the input fields. If no index and no
bit number has been entered, the fields remain empty.
7. Click the "Add" button in the parameter list to the right of the first free line.
The parameter is now inserted in the parameter list.
8. Repeat steps 5 to 7 for each drive object that you want to create in the parameter list.
9. Click the "Save List" button to save the parameter list to the memory card of the drive
(OEM/SINAMICS/HMI/PARLISTS).
A new tab is created for the new parameter list. The name of the parameter list appears
in the tab. You can view the actual parameter values and change them when required via
this tab.
10.If you want to change the order of the parameter lists, move the parameter list (tab) to the
desired position using drag and drop or with the aid of the "UP" and "DOWN" buttons.
412
Drive parameters - specifying the parameter list
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4