Table 7- 6
Parameter number
p0233
p0234
p0290
p1082
p1800
p1802
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Parameter settings for sine-wave filters
Name
Power unit motor reactor
Power unit sine-wave filter
capacitance
Power unit overload response
Maximum speed
Pulse frequency
Modulator modes
Basic functions
7.4 Sinusoidal filter
Setting
Filter inductance
Filter capacitance
Disable pulse frequency reduction
Fmax filter / pole pair number
Nominal pulse frequency of the filter
Space vector modulation without
overload