Characteristics of the parameter channel
● One 16-bit address exists for each parameter number and subindex.
● Concurrent access by several additional PROFIBUS masters (master class 2) or
● Transfer of different parameters in one access (multiple parameter request).
● Transfer of complete arrays or part of an array possible.
● Only one parameter request is processed at a time (no pipelining).
● A parameter request/response must fit into a data set (e.g. PROFIBUS: Max. 240 bytes).
● The request or the response header is user data.
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Figure 11-8
Reading and writing data
PROFINET IO supervisor (e.g. commissioning tool).
11.1 Communication according to PROFIdrive