Vector control
5.15 Efficiency optimization
Function diagrams (see SINAMICS S120/S150 List Manual)
• 6722 Vector control - Field weakening characteristic, Id setpoint (ASM, p0300 = 1)
• 6723 Vector control - Field weakening controller, flux controller (p0300 = 1)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
• r0077 CO: Torque-generating current setpoint
• r0331 Actual motor magnetizing current / short-circuit current
• p1570 CO: Flux setpoint
• p1580 Efficiency tuning
234
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Drive functions