PE6000 User Manual
Function
Code
P4-11
P4-00
P4-01
Figure 5-7 Setting of two-line mode 2
As shown in the preceding figure, if K1 is ON, the AC drive instructs forward rotation when K2
is OFF, and instructs reverse rotation when K2 is ON. If K1 is OFF, the AC drive stops.
2: Three-line mode 1
•
In this mode, DI3 is RUN enabled terminal, and the direction is decided by DI1 and DI2. The
parameters are set as below:
Function
Code
P4-11
P4-00
P4-01
P4-02
Parameter Name
Terminal command mode
DI1 function selection
DI2 function selection
Parameter Name
Terminal command mode
DI1 function selection
DI2 function selection
DI3 function selection
Value
1
1
2
Value
2
1
2
3
107
Description of Function Codes
Function Description
Two-line 2
RUN enabled
Forward or reverse
direction
PE6000
Function Description
Three-line 1
Forward RUN (FWD)
Reverse RUN (REV)
Three-line control