PE6000 User Manual
Function
Parameter Name
Code
A5-04
Rapid current limit
Current detection
A5-05
compensation
A5-06
Undervoltage threshold
SVC optimization mode
A5-07
A5-08
Dead-zone time adjustment
A5-09
Overvoltage threshold
A6-00
AI curve 4 minimum input
Corresponding setting of AI
A6-01
curve 4 minimum input
A6-02
AI curve 4 inflexion 1 input
Corresponding setting of AI
A6-03
curve 4 inflexion 1 input
A6-04
AI curve 4 inflexion 2 input
Corresponding setting of AI
A6-05
curve 4 inflexion 2 input
A6-06
AI curve 4 maximum input
Corresponding setting of AI
A6-07
curve 4 maximum input
A6-08
AI curve 5 minimum input
Corresponding setting of AI
A6-09
curve 5 minimum input
A6-10
AI curve 5 inflexion 1 input
Corresponding setting of AI
A6-11
curve 5 inflexion 1 input
A6-12
AI curve 5 inflexion 2 input
Corresponding setting of AI
A6-13
curve 5 inflexion 2 input
A6-14
AI curve 5 maximum input
Corresponding setting of AI
A6-15
curve 5 maximum input
Jump point of AI1 input
A6-24
corresponding setting
selection
Group A6: AI Curve Setting
Setting Range
0: Disabled1: Enabled
0–100
60.0%–140.0%
0: No optimization
1: Optimization mode 1
100%–200%
200.0–2500.0 V
-10.00 V to A6-02
-100.0%–100.0%
A6-00 to A6-04
-100.0%–100.0%
A6-02 to A6-06
-100.0%–100.0%
A6-06 to 10.00 V
-100.0%–100.0%
-10.00 V to A6-10
-100.0%–100.0%
A6-08 to A6-12
-100.0%–100.0%
A6-10 to A6-14
-100.0%–100.0%
A6-12 to 10.00 V
-100.0%–100.0%
-100.0%–100.0%
73
Function Code Tables
Default
Property
☆
1
☆
5
☆
100.0%
☆
1
☆
150%
Model
☆
dependent
☆
0.00V
☆
0.0%
☆
3.00V
☆
30.0%
☆
6.00V
☆
60.0%
☆
10.00V
☆
100.0%
☆
-10.00V
☆
-100.0%
☆
-3.00V
☆
30.0%
☆
3.00V
☆
30.0%
☆
10.00V
☆
100.0%
☆
0.0%