P4-33
AI curve selection
Setting for AI less
P4-34
than minimum input
P4-35
DI1 delay time
P4-36
DI2 delay time
P4-37
DI3 delay time
DI valid mode
P4-38
selection 1
Setting Range
Unit's digit (AI1 curve selection)
1: Curve 1 (2 points, see P4-13 to P4-16)
2: Curve 2 (2 points, see P4-18 to P4-21)
3: Curve 3 (2 points, see P4-23 to P4-26)
4: Curve 4 (4 points, see A6-00 to A6-07)
5: Curve 5 (4 points, see A6-08 to A6-15)
Ten's digit (AI2 curve selection)
Curve 1 to curve 5 (same as AI1)
Hundred's digit (AI3 curve selection)
Curve 1 to curve 5 (same as AI1)
Unit's digit (Setting for AI1 less than
minimum input)
0: Minimum value
1: 0.0%
Ten's digit (Setting for AI2 less than
minimum input)
0, 1 (same as AI1)
Hundred's digit (Setting for AI3 less than
minimum input)
0, 1 (same as AI1)
0.0–3600.0s
0.0–3600.0s
0.0–3600.0s
0: High level valid
1: Low level valid
Unit's digit (DI1 valid mode)
Ten's digit (DI2 valid mode)
Hundred's digit (DI3 valid mode)
Thousand's digit (DI4 valid mode)
Ten thousand's digit (DI4 valid mode)
54
PE6000 User Manual
Default
Property
321
00
0.0s
0.0s
0.0s
00000