Operation, Display and Application Examples
as adjustment speed and accuracy, for the two units separately based on the actual conditions.
Switchover between the two units can be implemented automatically or by means of an external
DI terminal.
3.7.7 Swing Mode
For the textile and chemical fiber processing equipment, the swing function improves the
uniform density of traversing and winding, as shown in Figure 3-22. The function is set in PB-00 to
PB-04. For details, see the description of these function codes.
Figure 3-22
PB-01 >0%
PB-02: Jump frequency
amplitude
PB-03: Swing frequency
cycle
PB-04: Triangular wave
rising time coefficient
3.7.8 Multi-Speed Mode
In scenarios where the running frequency of the AC drive need not be adjusted continuously
and only several frequencies are required, the multi-speed control can be used. The PE6000
supports a maximum of 16 running frequencies, which are implemented by state combinations
of four DI terminals. Set the function codes corresponding to DI terminals to a value among 12
to 15, and then the DI terminals are specified as the multi-frequency input terminals. The
multiple frequencies are set based on the multi-frequency table in group PC. In addition, you
need to set P0-03 (Main frequency source X selection) to 6 (Multi- reference). The following
figure shows how to set the multi-speed function.
Swing function
32
PE6000 User Manual