PE6000 User Manual
Figure 3-25 Function code setting for fixed length control
P4-04 = 27
(Length pulses
input)
DI5
P4-00 to P4-09
=28
(Length reset)
Note
In the fixed length control mode, the direction cannot be identified and only the length shall
•
be calculated based on the number of pulses.
•
Only DI5 can be allocated with the function "Length count input".
An automatic stop system can be implemented if the length reached signal output by the DO
•
is fed back to the AC drive input terminal with the stop function.
Figure 3-26 Common application example of the fixed length control function
PB-05
PB-07
PB-06
PB-05 = 11
PB-06 = 11
CME
COM
DI1
DI2
DI3
DI4
DI5
CME
35
Operation, Display and Application Examples
P5-00 to P5-05 = 10
(Length reached)
PB-06 = 0
PE6000
PB-05(Set length)
P0-02 = 1, P4-00 = 1
P4-01 = 3, P4-02 = 4
P4-11 = 2
P4-03 = 26, P4-04 = 27
PB-07(Number of
pulses per meter).
P5-04 = 10