Pioneer PE6000 Series User Manual page 139

Table of Contents

Advertisement

PE6000 User Manual
Any current reaching 1
P8-38
Any current reaching 1 amplitude
P8-39
Any current reaching 2
P8-40
Any current reaching 2 amplitude
P8-41
If the output current of the AC drive is within the positive and negative amplitudes of any current
reaching detection value, the corresponding DO becomes ON.
The PE6000 provides two groups of any current reaching detection parameters, including
current detection value and detection amplitudes, as shown in the following figure.
Figure 5-23 Any current reaching detection
P8-36
Setting Range
Setting Range
Setting Range
Setting Range
P8-37
Default
0.0%–300.0% (rated motor current)
Default
0.0%–300.0% (rated motor current)
Default
0.0%–300.0% (rated motor current)
Default
0.0%–300.0% (rated motor current)
139
Description of Function Codes
100.0%
0.0%
100.0%
0.0%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents