Display the VLAN-Stacking configuration for a switchport using the command
INTERFACE mode, as shown in
Figure 46-3. Displaying the VLAN-Stack Configuration on a Layer 2 Port
FTOS#show run interface gi 7/0
!
interface GigabitEthernet 7/0
no ip address
switchport
vlan-stack access
no shutdown
FTOS#show run interface gi 7/12
!
interface GigabitEthernet 7/12
no ip address
switchport
vlan-stack trunk
no shutdown

Enable VLAN-Stacking for a VLAN

To enable VLAN-Stacking for a VLAN:
Task
Enable VLAN-Stacking for the VLAN.
Display the status and members of a VLAN using the
Members of a VLAN-Stacking-enabled VLAN are marked with an M in column Q.
Figure 46-4. Display the Members of a VLAN-Stacking-enabled VLAN
FTOS#show vlan
Codes: * - Default VLAN, G - GVRP VLANs
NUM
*
1
2
3

Configure the Protocol Type Value for the Outer VLAN Tag

The Tag Protocol Identifier (TPID) field of the S-Tag is user-configurable:
Task
Select a value for the S-Tag TPID.
Default: 9100
Display the S-Tag TPID for a VLAN using the command
mode. FTOS displays the S-Tag TPID only if it is a non-default value.
954
|
Service Provider Bridging
Figure
Status
Q Ports
Active
U Gi 13/0-5,18
Inactive
Inactive
46-3.
Command Syntax
INTERFACE VLAN
show vlan
command from EXEC Privilege mode.
Command Syntax
CONFIGURATION
show running-config
show config
from
Command Mode
vlan-stack compatible
Command Mode
vlan-stack protocol-type
from EXEC privilege