Figure 34-14. PIM-SM snooping: show ip mroute snooping
FTOS#show ip mroute snooping
IPv4 Multicast Snooping Table
(*, 224.0.0.0), uptime 17:46:23
Incoming vlan: Vlan 2
Outgoing interface list:
GigabitEthernet 4/13
(*, 225.1.2.1), uptime 00:04:16
Incoming vlan: Vlan 2
Outgoing interface list:
GigabitEthernet 4/11
GigabitEthernet 4/13
(165.87.1.7, 225.1.2.1), uptime 00:03:17
Incoming vlan: Vlan 2
Outgoing interface list:
GigabitEthernet 4/11
GigabitEthernet 4/13
GigabitEthernet 4/20
Figure 34-15. PIM-SM snooping: show running-config
FTOS#show running-config pim
!
ip pim snooping enable
Figure 34-16. PIM-SM snooping: show configuration
FTOS(conf-if-vl-2)#show config
!
interface Vlan 2
no ip address
tagged GigabitEthernet 4/11-13,20-23
no shutdown
FTOS(conf-if-vl-2)#