Advertisement

There are three types of ports in PVLAN:
Host Ports—these ports are the ones that Private VLAN aims to isolate. They are connected to
end-stations.
Promiscuous Ports—these ports are members of the primary VLAN, and function as gateways to the
primary and secondary VLANs.
Trunk Ports—trunk ports carry tagged traffic between switches. They have promiscuous and trunk
ports as members.
Figure 39-2. PVLAN: Primary and Secondary VLANs
Host Port

Important Points to Remember

Even if secondary VLANs are operationally down, if the primary VLAN is operationally up, Layer 3
traffic is still be transmitted across the secondary VLANs.
PVLAN ports cannot be added to regular VLANs. Conversely, regular VLAN ports cannot be added to
PVLANs.
If a promiscuous or host port is untagged in a VLAN, and it receives a tagged packet in the same
VLAN, the packet will NOT be dropped.
A primary VLAN and each of its secondary VLANs decrement the available number of VLAN IDs in
the switch.

Configure Private VLANs

Configuring Private VLANs is a 3-step process:
1.
Configure PVLAN Ports
2.
Place PVLAN Ports in a Secondary VLAN
3.
Place the Secondary VLANs in a Primary VLAN
832
|
Private VLANs
Primary VLAN
Host Port
Isolated
VLAN
Community
VLAN
Promiscuous
Port
Trunk Port
Network
Server