Changes made do not affect any ongoing debounces. The timer changes take affect from the next
debounce onward.
Assign a debounce time to an interface
Command Syntax
link debounce time [milliseconds]
Figure 20-28. Setting Debounce Time
FTOS(conf)#int gi 3/1
FTOS(conf-if-gi-3/1)#link debounce time 150
FTOS(conf-if-gi-3/1)#=
Show debounce times in an interface
show interface debounce
port ]
Figure 20-29. Showing Debounce Time
FTOS#
FTOS#show interfaces debounce gigabitethernet 3/1
Interface
GigabitEthernet 3/1
FTOS#
Note: FTOS rounds the entered debounce time up to the nearest hundredth.
Note in
Figure 20-28
Disable ports when one only SFM is available (E300 only)
Selected ports can be shut down when a single SFM is available on the E300 system. Each port to be shut
down must be configured individually.
Command Mode
INTERFACE
[ type ] [ slot/
EXEC Privilege
Time(ms)
200
that the timer was set at 150 ms, but appears as 200 in
Purpose
Enter the time to delay link status change notification on this
interface.
Range: 100-5000 ms
•
Default for Copper is 3100 ms
•
Default for Fiber is 100 ms
Show the debounce time for the specified interface.
Enter the interface type keyword followed by the type
of interface and slot/port information:
•
For a 10/100/1000 Ethernet interface, enter the
keyword GigabitEthernet followed by the slot/
port information.
•
For a Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port
information.
•
For a 10 Gigabit Ethernet interface, enter the
keyword TenGigabitEthernet followed by the
slot/port information.
Figure
20-29.