MIP Database (MIP-DB): Every MIP must maintain a database of all other MEPs in the MA that
have announced their presence via CCM
Task
Display the MEP Database.
FTOS#show ethernet cfm maintenance-points remote detail
MAC Address: 00:01:e8:58:68:78
Domain Name: cfm0
MA Name: test0
Level: 7
VLAN: 10
MP ID: 900
Sender Chassis ID: FTOS
MEP Interface status: Up
MEP Port status: Forwarding
Receive RDI: FALSE
MP Status: Active
Display the MIP Database.
MP Database Persistence
Task
Set the amount of time that data
from a missing MEP is kept in
the Continuity Check Database.
86
|
802.1ag
Command Syntax
show ethernet cfm maintenance-points remote detail
domain
expired
|
{
|
} |
level
name
show ethernet cfm mipdb
Command Syntax
database hold-time minutes
Default: 100 minutes
Range: 100-65535 minutes
active
[
waiting
|
]
Command Mode
EXEC Privilege
EXEC Privilege
Command Mode