View the amount of power that a port is consuming using the
privilege mode.
Figure 36-2. PoE Allocation Displayed with show power inline Command
FTOS(conf-if-range-gi-0/1-48)#do show power inline
Interface
---------
Gi 0/1
Gi 0/2
Table 36-3
Table 36-3. show power inline Field Description
Field
Interface
Admin
Inline Power Allocated
Inline Power Consumed
Class
View the total power consumption of the chassis using the
privilege mode.
Figure 36-3. PoE Consumed, Allocated, and Available with show power detail Command
FTOS(conf-if-range-gi-0/1-48)#do show power detail
Unit
Total
Power
Available
(Watts)
-------------------------------------------------------------------------------
0
788
|
Power over Ethernet
Admin
Inline Power
Allocated
(Watts)
-----
------------
auto
0.00
auto
7.00
describes the fields that the
Port Number
Displays all PoE-enabled ports.
Displays the administrative mode of the interface:
auto indicates that power is supplied according to the requirements of the powered device.
static indicates that the maximum configured amount of power is supplied to the powered
device.
Displays the amount of power that is allocated to a port when sufficient power is available.
When sufficient power is not available for particular port, then inline power is not supplied to
that port. If you insert an additional power supply, or when the priority of the port is sufficiently
increased, then the system supplies the allocated power to the port.
Displays the amount of power that a powered device is consuming.
Displays the type of powered device: Class 0, Class 1, Class 2, Class 3, or Class 4. Displays
NO_DEVICE if no PD is connected.
Logic
Inline
Power
Power
Consumed
Available
(Watts)
(Watts)
470.00
150
320.00
show power inline
Inline Power
Class
Consumed
(Watts)
------------
-----
0.00
NO_DEVICE
3.20
2
show power inline
command displays:
show power detail
Inline
Inline
Power
Power
Allocated
Consumed
(Watts)
(Watts)
308.00
190.00
command from EXEC
User
Priority
----------
Low
Low
command from EXEC
Inline
Power
Remaining
(Watts)
12.00