Show Sflow On A Line Card - Dell Force10 C150 Configuration Manual

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Figure 47-3. Command Example:
FTOS#show sflow interface gigabitethernet 1/16
Gi 1/16
Configured sampling rate
Actual sampling rate
Sub-sampling rate
Counter polling interval
Samples rcvd from h/w
Samples dropped for sub-sampling :6
The configuration, shown in
Figure 47-4. Command Example:
FTOS#show running-config interface gigabitethernet 1/16
!
interface GigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow enable
sflow sample-rate 8192
no shutdown

Show sFlow on a Line Card

Use the following command to view sFlow statistitics on a specified line card:
Command Syntax
show sflow linecard slot-number
Figure 47-5
is a sample output from the
Figure 47-5. Command Example:
FTOS#show sflow linecard 1
Linecard 1
Samples rcvd from h/w
Samples dropped for sub-sampling :69
Total UDP packets exported
UDP packets exported via RPM
UDP packets dropped
show sflow interface
:8192
:8192
:2
:15
:33
Figure
47-2, is also displayed in the running configuration
show running-config interface
Command Mode
EXEC
show sflow linecard
show sflow linecard
:165
:77
:77
:
Purpose
Display sFlow configuration information and statistics on
the specified interface.
command:
(Figure
47-4):
sFlow | 977