To enable EdgePort on an interface, use the following command:
Task
Enable EdgePort on an interface.
The EdgePort status of each interface is given in the output of the command
shown in
FTOS Behavior: Regarding
1 If the interface to be shutdown is a port channel then all the member ports are disabled in the hardware.
2 When a physical port is added to a port channel already in error disable state, the new member port will
3
4
842
|
Per-VLAN Spanning Tree Plus
Figure
40-4.
also be disabled in the hardware.
When a physical port is removed from a port channel in error disable state, the error disabled state is
cleared on this physical port (the physical port will be enabled in the hardware).
reset linecard
The
command does not clear the error disabled state of the port or the hardware disabled
state. The interface continues to be disables in the hardware.
The error disabled state can be cleared with any of the following methods:
Perform an shutdown command on the interface.
Disable the shutdown-on-violation command on the interface (no spanning-tree stp-id portfast
[bpduguard | [shutdown-on-violation]] ).
Disable spanning tree on the interface (no spanning-tree in INTERFACE mode).
Disabling global spanning tree (no spanning-tree in CONFIGURATION mode).
Command Syntax
spanning-tree pvst edge-port
[
bpduguard |
shutdown-on-violation
bpduguard shutdown-on-violation
Command Mode
INTERFACE
]
show spanning-tree pvst