Parameter overview
Parameter
Func-
Name
tion
Motor excitation cur-
82
rent
83
Motor rated voltage
84
Rated motor frequency 0.01Hz
Motor constant (R1)
90
Motor constant (R2)
91
Motor constant (L1)
92
Motor constant (L2)
93
Tab. 6-1:
Parameter overview (24)
6 - 24
Incre-
Initial
Setting
ments
Value
Range
0–500A/
0–3600A *
0.01A/
9999
0.1A *
9999
0.1V
400V
0–1000V
50Hz
10–120Hz
0–50Ω/
0–400mΩ *
0.001Ω/
9999
0.01mΩ *
9999
0–50Ω/
0–400mΩ *
0.001Ω/
9999
0.01mΩ *
9999
0–50Ω
(0–1000mH)/
0.001Ω
0–3600mΩ
(0.1mH)
9999
(0–400mH) *
0.01mΩ
(0.01mH) *
9999
0–50Ω
(0–1000mH)/
0.001Ω
0–3600mΩ
(0.1mH)/
9999
(0–400mH) *
0.01mΩ
(0.01mH) *
9999
Description
Tuning data
(The value measured by offline
auto tuning is automatically set.)
* The increments and setting
range differ according to the
inverter capacity.
(01800 or less/02160 or more)
Use the Mitsubishi motor (SF-JR,
SFHRCA) constants
Set the rated motor voltage.
Set the rated motor frequency.
Tuning data
(The value measured by offline
auto tuning is automatically set.)
* The increments and setting
range differ according to the
inverter capacity.
(01800 or less/02160 or more)
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
Tuning data
(The value measured by offline
auto tuning is automatically set.)
* The increments and setting
range differ according to the
inverter capacity.
(01800 or less/02160 or more)
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
Tuning data
(The value measured by offline
auto tuning is automatically set.)
* The increments and setting
range differ according to the
inverter capacity.
(01800 or less/02160 or more)
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
Tuning data
(The value measured by offline
auto tuning is automatically set.)
* The increments and setting
range differ according to the
inverter capacity.
(01800 or less/02160 or more)
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
Parameter
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled