Mitsubishi Electric FR-A700 Instruction Manual page 504

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Monitor display and monitor output signals
Types of Monitor
Input terminal status
Output terminal status
Option input terminal
states
Option output terminal
states
PLC function output
Tab. 6-92: Monitor description list (3)
Frequency setting to output terminal status on the PU main monitor are selected by "other
monitor selection" of the parameter unit (FR-PU04/FR-PU07).
Position pulse and orientation status function when used with an option (FR-A7AP). When
orientation control is invalid, "0" remains displayed and these functions are invalid.
Feedback pulse functions when the option (FR-A7AP) is used and vector control is
performed.
The cumulative energizing time and actual operation time are accumulated from 0 to 65535
hours, then cleared, and accumulated again from 0. When the operation panel (FR-DU07)
is used, the time is displayed up to 65.53 (65530h) on the assumption that 1h = 0.001, and
thereafter, it is added up from 0.
The actual operation time is not added up if the cumulative operation time before power
supply-off is less than 1h.
When using the parameter unit (FR-PU04/FR-PU07), "kW" is displayed.
The setting depends on capacities. (01800 or less/02160 or more)
Since the panel display of the operation panel (FR-DU07) is 4 digits in length, the monitor
value of more than "9999" is displayed "----".
6 - 324
Pr. 52
Increments
PU Main
DU LED
Monitor
55
56
57
0.1%
Full-scale
Pr. 54 (CA)
value of the
Pr. 158 (AM)
terminal CA
Setting
and AM
70
100%
Parameter
Description
ON/OFF status of the input terminal is
displayed on the PU
(Refer to page 6-327 for DU display)
ON/OFF status of the output terminal
is displayed on the PU
(Refer to page 6-327 for DU display)
ON/OFF status of the input terminal of
the digital input option (FR-A7AX) is
displayed on the DU
(Refer to page 6-327 for DU display)
ON/OFF status of the output terminal
of the digital output option (FR-A7AY)
and relay output option (FR-A7AR) is
displayed on the DU
(Refer to page 6-327 for DU display)
Desired values can be output from ter-
minal CA and AM using the PLC func-
tion. Refer to the FR-A700 PLC
function programming manual for
details of the PLC function.