Mitsubishi Electric FR-A700 Instruction Manual page 316

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Position control by vector control
Pulse monitor selection (Pr. 430)
The status of various pulses during running is displayed. Set "6" in Pr. 52 "DU/PU main display
data selection" to display output frequency monitor.
Pr. 430
0
1
2
3
4
5
9999
Tab. 6-25: Pulse monitor selection
NOTES
Count the number of pulses when the servo is on.
The cumulative pulse value is cleared when the base is shut off or the clear signal (CLR) is
turned on.
Changing the terminal assignment using Pr. 178 to Pr. 189 "Input terminal function
selection" may affect the other functions. Make setting after confirming the function of each
terminal.
6 - 136
Description
The cumulative command pulse value is dis-
played.
The cumulative feedback pulse value is dis-
played.
The droop pulses are monitored.
Frequency monitor is displayed. (initial value)
Display Range
Display Range
(FR-DU07)
(FR-PU04/FR-PU07)
Lower 4 digits
Lower 5 digits
Upper 4 digits
Upper 5 digits
Lower 4 digits
Lower 5 digits
Upper 4 digits
Upper 5 digits
Lower 4 digits
Lower 5 digits
Upper 4 digits
Upper 5 digits
Parameter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents